Rackmount PRO1500E Spécifications Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
Rear PaneL
4
Output Socket
5
Narrow/Wide Selector
1
Battery 12V, 24V, 48V, 96V
2
Input Protector
3
Input Socket
Note:
Product specifications are subject to change without prior notice.
Indications:
“P” represents 24VDC
“R” represents 48VDC
“L” represents 96VDC
500VA
300W
IPS500MODELS
1000VA
600W
IPS1000
3000VA
2500W
IPS3000 (P/R)
5000VA
4200W
IPS5000 (R/L)
Volt-Amp
Watt
Capacity
2000VA
1200W
IPS2000
INPUT
Nominal Voltage
Acceptable
Voltage Range
Narrow Range
Wide Range
Voltage Regulation
Frequency
Output Waveform
Transfer Time
OUTPUT
Nominal Voltage
Frequency Regulation
Charging Current
BATTERY
DC Voltage
Overcharge Protect
LCD
10Amp ±1Amp8Amp ±1Amp
12V
15V
NA User Friendly LCD Display
24V
30V
24V/48V
20Amp
30V/60V
INDICATION
110/120VAC or 220/230/240VAC
90~145VAC or 170~280VAC
50~145VAC or 90~280VAC
Modified Sinewave
10-20ms Typical, 40ms Max
50Hz or 60Hz
120V or 230VAC
10% or -18% (Battery Mode)
±0.1Hz (Battery Mode)
Full specifications
3 type of capacity model available: IPS500, IPS1000, IPS2000.
Super efficient DC to AC conversion, minimizing charging losses.
High frequency technology, provides critical overload protection.
User selectable for accepting wider input voltage.
Full automatic start operation and silent operation.
Compact size for convenient use and storage.
Small scale and cost effective inverter for home appliances and office equipment.
Two steps intelligent charging control to reduce the recharging time.
Eco-friendly and non-polluting (green device).
IPS series
inverter UPS
48V/96V
10/20Amp
60V/120V
AC to AC Efficiency
DC to AC Efficiency
Protection
Environment
GENERAL
Noise Level
Net Weight (Without Batteries) (kgs)
Dimension (mm) D×W×H
2.32.0
AC Mode
Battery Mode
LED
Fault
> 95%
> 80%
255×80×224 470×350×110
Less than 50dB Less than 60dB
Discharge, Overcharge and Overload Protections
0~40°C, 0~90°C relative humidity (Non-Condensing)
2.5 8.5 9.0
Green Lighting
Yellow Lighting
Green Flashing every 2 seconds
Sounding every 2 seconds
Sounding every 0.5 second
Continuously Sounding
Red Flashing every 0.5 second
Red Lighting
Charging Mode
Overload
Low Battery Alarm
Overload Alarm
Fault Alarm
NA